Raymarine ST40 User Manual

Browse online or download User Manual for Sports and recreation Raymarine ST40. Raymarine ST40 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Distributed by
Any reference to Raytheon or
RTN in this manual should be
interpreted as Raymarine.
The names Raytheon and RTN
are owned by the
Raytheon Company.
Page view 0
1 2 3 4 5 6 ... 46 47

Summary of Contents

Page 1

Distributed by Any reference to Raytheon or RTN in this manual should be interpreted as Raymarine. The names Raytheon and RTN are owned by the Ra

Page 2 - Handbook

Chapter 1: Operation1Chapter 1: OperationYour ST40 Depth instrument:• Provides depth information, in either feet (FT), metres (M) orfathoms (FA), as s

Page 3 - 158_2cov.p65 01/05/01, 13:552

2 ST40 Depth Instrument Owner’s HandbookNORMAL OPERATION (sheet 1)DepthMinimumdepthShallowalarmD4658-2Notes:Screens other than the Depth screen, arete

Page 4 - Important information

Chapter 1: Operation3ST40 DEPTHST40 DEPTHST40 DEPTHST40 DEPTHST40 DEPTHNORMAL OPERATION (sheet 2)D4659-2To/from Deep alarm screen(sheet 1)Deep anchora

Page 5 - 158_2pre.p65 01/05/01, 13:552

4 ST40 Depth Instrument Owner’s HandbookAdjusting display backlighting and contrastDuring normal operation, pressDuring normal operation, pressThe cur

Page 6 - Contents

Chapter 1: Operation51.2 AlarmsAlarm indicationsShallow alarmDepth is equal to or less than the shallow alarm threshold.Alarm continues until cancelle

Page 7 - 158_2pre.p65 01/05/01, 13:554

6 ST40 Depth Instrument Owner’s HandbookEnabling/disabling alarmsYou can enable or disable any alarm function (i.e. switch it on or off )by selecting

Page 8 - 158_2pre.p65 01/05/01, 13:555

Chapter 2: Maintenance and Fault Finding7Chapter 2: Maintenance and Fault Finding2.1 MaintenanceServicing and safety• Raymarine equipment should be se

Page 9 - Parts supplied

8 ST40 Depth Instrument Owner’s HandbookInstrumentCertain atmospheric conditions may cause a small amount ofcondensation to form on the instrument win

Page 10 - Silencing alarms

Chapter 2: Maintenance and Fault Finding9ActionRecharge your vessel’s battery assoon as possibleActionEnsure that reading stabilises whenclear of dist

Page 11 - NORMAL OPERATION (sheet 1)

10 ST40 Depth Instrument Owner’s HandbookA group of SeaTalkinstruments notworkingActionCheck the security of SeaTalkconnectors between functioning and

Page 12 - NORMAL OPERATION (sheet 2)

ST40 DepthInstrumentOwner’sHandbookDocument number: 81158_2Date: 1st May 2001158_2cov.p65 01/05/01, 13:551

Page 13 - ADJUST CONTRAST

Chapter 3: Installation11Chapter 3: InstallationThis chapter describes how to install the ST40 Depth instrument, andassociated Depth transducer. The t

Page 14 - 1.2 Alarms

12 ST40 Depth Instrument Owner’s Handbook• The equipment is supplied from a different battery from that used forengine start. Voltage drops below 10 V

Page 15 - Enabling/disabling alarms

Chapter 3: Installation1357 mm(2.25 in)51 mm(2.0 in)D4643-1Note: If you intend fitting a nonstandard transducer, extra tools maybe requiredSite requir

Page 16 - Servicing and safety

14 ST40 Depth Instrument Owner’s HandbookThe transducer should be sited within the clear water flow areasindicated by the shaded areas in the followin

Page 17 - Fixing faults

Chapter 3: Installation15Depth transducer maximum angleD4350-2InstrumentCAUTION:The presence of moisture at the rear of the instrument could causedama

Page 18 - 1 minute

16 ST40 Depth Instrument Owner’s Handbook3.2 ProceduresAdapt these procedures as appropriate, to suit your individualrequirement.CAUTION:Where it is n

Page 19 - Assistance

Chapter 3: Installation17Connections to the instrumentYou can connect your instrument:• Directly to the depth transducer as a stand-alone master instr

Page 20 - EMC installation guidelines

18 ST40 Depth Instrument Owner’s HandbookStand-alone connectionsCAUTIONEnsure that the power supply for each stand-alone ST40instrument is protected b

Page 21 - Tools required

Chapter 3: Installation195 A circuit breakerRed (+ve)12 V dc supply(e.g. coursecomputeror battery)Uninsulated wire(screen) -veD4824-2Typical SeaTalk c

Page 22 - 89 mm (3.50 in)

20 ST40 Depth Instrument Owner’s Handbook2 Cut hole57 mm (2.25 in) cutterD4760-1Peel protective sheets from gasket3D4770-14 Stick gasket to rear of in

Page 23 - Transducer siting

Copyright © Raymarine Limited 2001158_2cov.p65 01/05/01, 13:552

Page 24 - CAUTION:

Chapter 3: Installation21D4819-15 Screw stud into instrument5 Fit instrumentD4817-16 Feed cables through clamping bracket,connect cables then secure i

Page 25 - Fitting transducer

22 ST40 Depth Instrument Owner’s HandbookD4646-1To bracket mount your ST40 instrument, do so in accordance with theInstruction Sheet, which is include

Page 26 - Connections to the instrument

Chapter 4: Calibration23Chapter 4: Calibration4.1 IntroductionThe procedures in this Chapter must be carried out before theequipment is used operatio

Page 27 - SeaTalk connections

24 ST40 Depth Instrument Owner’s HandbookDepth offsetsWARNING:The use of incorrect offset values could result in misleading depthinformation being dis

Page 28 - Fitting the instrument

Chapter 4: Calibration25USER CALIBRATIONEntryscreenD4662-2Depthresponsefor approximately 2 secondshold down andDepthunits15 (fast)1 (slow)CALWARNING:C

Page 29 - 57 mm (2.25 in) cutter

26 ST40 Depth Instrument Owner’s Handbook4.3 Intermediate calibrationIntermediate calibration enables you to:• Check the instrument software version.•

Page 30 - 5 Fit instrument

Chapter 4: Calibration27CALCALCALCAUTION:Do NOT switch the Boat Show mode on.This function must only be used fordemonstration purposes.EntryscreenD466

Page 31 - 3.3 Calibration requirement

28 ST40 Depth Instrument Owner’s Handbook158_2c04.p65 01/05/01, 13:5728

Page 32 - EMC conformance

Instrument Specification29Instrument SpecificationSupply voltage: 10 V to 16 V dc.Current consumption (12 V supply): 30 mA typical.70 mA with maximum

Page 33 - Depth offsets

30ST40 Depth Instrument Owner’s Handbook158_2spe.p65 01/05/01, 13:5730

Page 34 - USER CALIBRATION

PrefaceiImportant informationWARNINGAlthough your ST40 instrument is designed to give accurate andreliable performance, it should serve only as an aid

Page 35 - 4.4 Dealer calibration

Glossary31GlossaryEMC Electromagnetic Compatibility.FA Fathoms.FT Feet.KEEL When displayed on the Offset screen (during normal operation), or theDepth

Page 36 - DEALER CALIBRATION

32ST40 Depth Instrument Owner’s Handbook158_2glo.p65 01/05/01, 13:5732

Page 37

Index33IndexAAlarms 5–6enable/disable 6indications 5ranges 29setting thresholds 2, 3shallow alarm lock 23silencing 1switching on and off 2, 3BBackligh

Page 38 - Instrument Specification

34 ST40 Depth Instrument Owner’s HandbookLLock shallow alarm 23MMaintenance 7–8Minimum depth 1NNormal operation 2–4OOffset 1Operating procedures 1–4Op

Page 39

D4800-1TOPCut outshaded area onlyCut out hole57 mm (2.25 in)diameterST40 Instrument Template158_2tem.p65 01/05/01, 13:5735

Page 40 - Glossary

158_2tem.p65 01/05/01, 13:5736

Page 41

Document number: 84064-8April 2001Limited Warranty CertificateRaymarine warrants each new Light Marine/Dealer Distributor Product to be of good materi

Page 42 - 1, 23, 24

Factory Service CentersUnited States of America UK, Europe, Middle East, Far EastRaymarine Inc22 Cotton Road, Unit DNashua, NH 03063-4219

Page 43

ii ST40 Depth Instrument Owner’s Handbook158_2pre.p65 01/05/01, 13:552

Page 44

PrefaceiiiContentsImportant information ... iWARNING...

Page 45

iv ST40 Depth Instrument Owner’s HandbookChapter 3: Installation... 113.1 Planning your installa

Page 46 - Limited Warranty Certificate

PrefacevPrefaceThank you for purchasing a Raymarine product. We are sure yourST40 instrument will give you many years of trouble-free operation.This i

Page 47 - Factory Service Centers

vi ST40 Depth Instrument Owner’s HandbookParts suppliedD4665-2ST40 DepthInstrumentOwner'sHandbookWorldwideDistributorsST40 Depth instrumentFixing

Comments to this Manuals

No comments