ST30 Depth Operation and Installation Handbook
Chapter 3: Fault Finding
All Autohelm products are, prior to packing and shipping, subject to
comprehensive test and quality assurance programmes. However, if a
fault arises with the ST30 Depth, the following table will help to identify the
probable cause and provide the most likely cure.
Note:
After installation, poor performance may be experienced if the
surface of the depth transducer has not been 'wetted'. Wetting can take
up to 24 hours under normal conditions. The transducer can be 'wetted'
prior to launch by applying a mild detergent to the external face.
Fault Cause Action
Instrument display
blank
No supply to
instrument
Check supply
Check cabling and
security of connectors
Check circuit
breaker/fuse
Return ST30 Depth for
repair
No depth information Aereated water, boat
wakes or propeller
wash
Depth reading will
return to normal once
clear of disturbed
water
Feet/metres display
flashes continuously
Transducer cable or
connector fault
Check cabling and
security of transducer
connector
No exchange of
information between
SeaTalk instruments
SeaTalk cabling or
connector problem
Check security of
SeaTalk connectors
Remove instruments one
by one to isolate
faulty unit
Failure of a group of
instruments in a chain
Cabling or connector
problem
Check the security of
the connectors between
functioning and
non-functioning
instruments
Unable to enter
calibration
Calibration locked Refer to Calibration
lock/
unlock section