Chapter 2: Advanced Operation 23
How do I access User Calibration settings?
You can only access the calibration mode from Standby mode:
1. With the SmartPilot in Standby mode, press and hold the standby button for
2 seconds. The display will change to show DISPLAY CAL.
2. Press the disp button once, the display will now show USER CAL.
3. Press auto to enter User Calibration.
The first page of User Calibration will now be displayed.
4. To access other User Calibration pages, press disp to scroll down through the
items within that grouping:
5. When you reach an item you wish to adjust, use the -1, +1, -10 and +10 but-
tons (as appropriate) to change the value.
6. When you have made all the changes you want to make, press and hold
standby for two seconds to exit calibration mode and save changes.
User Calibration pages
AutoTack angle (SAILBOAT only)
The AutoTack angle is the angle through which the boat will turn when you select
an automatic tack.
Gybe inhibit (SAILBOAT only)
With gybe inhibit on:
• you will be able to perform an AutoTack into the wind
• to prevent accidental gybes, the SmartPilot will prevent the boat from per-
forming an AutoTack away from the wind
With gybe inhibit off, you can perform an AutoTack into or away from the wind.
Screen Text Options
AUTO TACK 40° to 125° in 1° steps
Screen Text Options
GYBE STOP ON (Default) = Gybe inhibit on (gybes prevented)
OFF = Gybe inhibit off (gybes permitted)