2-
12
ST50 PLUS RADAR Operation and installation Handbook
I
I
Step 1. Loosen the 4 clamping bolls
securing the radome and remove the
radome cover. -The clamping bolts are
captive and should remain in the lower
flange assembly.
Step 2. Remove watertight gland and
grommet where the interconnect cable
enters the radome base.
Remove shield jacket retaining plate.
Step 3. Slide gland nut and the rubber
grommet onto the cable and insert the
connecting cable into the radome base.
Secure the watertight gland.
Step 4. Connect the cable leads to
terminal board
Jl,
using clamping tool
supplied. Ground the shield with the lug
to cable clamp bolt provided. Dress the
wire harness with cable clamps or
tie-
raps as necessary for neatness.
)
Section 2. installation
The cable entrance is provided at the rear of the radome unit. If the unit
is mounted on a hollow mast, the cable may be run inside the mast and
then fed through the radar’s cable entrance.
Before wiring the scanner unit, confirm that the interunit cable is not
connected and power is not applied to the display unit. Connect the
cable leads onto terminal strip JI, using clamping tool as shown below.
Tie shield jacket by retaining plate.
I
A
AlI----
-----
T
Coax. 50 ohms
ELK
-R
.
-----
/
WHT
---.
;
YEL
I
0
I
I
I @
T RED
I
I
I
-
SHIELDED WIRE
LARGE WIRE
SMALL WIRE
I
-----J
Fig. 2-10 Wiring Diagram for ST50 Radome Antenna Unit
DC-R
Tl/GS
TUNVIPW
TUNIISHM
+12V/BP
-0V
HV
Fig. 2-9 Connecting Procedure for Radome Antenna Unit