14
Priority: Distribution List:
URGENT
(For immediate attention)
Distributors & Service Agents
ROUTINE
(Action at next Service Call)
Installing Agents & BoatBuilders
Key Stockists
INFORMATION ONLY
Internal Release
Raymarine,
Raymarine House,
Quay Point,
Portsmouth,
Hampshire,
PO6 3TD, UK.
T: +44 (0)23 9269 3611 ext 2023
F: +44 (0)23 9266 1228
Raymarine Inc.,
21 Manchester Street
Merrimack, NH 03054-4801
USA
T: 1-603-881-5200
F: 1-603-864-4756
www.raymarine.com
Technical Update
Issue Number: TU228
Page 1of 2
Date: 1
st
August 2005
Author:
Bob Sims
Product Description:
SmartPilot S1 & S1G Course Computers, Corepacks &
Systems
Serial Number(s): All
Subject
:
Fluxgate Compass Circuit Fault
Please be advised that infield feedback has highlighted a potential fluxgate compass circuit fault, which can affect current
S1 and S1G SmartPilot course computers.
The fault will cause the compass heading to drift, jump segments or show large inaccuracies.
The fault is associated with the wrongly reverse placement of the fluxgate drive AC coupling capacitor C43. The fault
does not affect all S1 Course Computers and is only triggered when the tolerance of the capacitor is at the limits of its
value specification.
The following service procedure should be taken to rectify faulty units:
¾Follow procedure over.
¾Remove PCB from Course Computer Case
¾Locate C43 Capacitor
¾Unsolder & remove from PCB
¾Replace and re-solder in reverse (see diagrams)
¾Replace PCB into case
¾15mins labour per unit can be claimed against warranty
¾For onboard service follow the normal warranty claims procedure
For further information contact Raymarine’s Technical Services Department.
Comments to this Manuals