S e a T a l k < - > N M E A
B r i d g e
Configuration example
Example 1:
In this example we configure the bridge, so that the NMEA baudrate is changed to 38400
baud.
– Find function ID for baudrate in table on page 22.
– Function ID for baudrate is 1
– Find value for 38400 baud in table on page 22.
– Value for 38400 baud is 8
1
Set NMEA port baudrate
1 = 300 baud
2 = 600 baud
3 = 1200 baud
4 = 2400 baud
5 = 4800 baud ( Default )
6 = 9600 baud
7 = 19200 baud
8 = 38400 baud
– Enter Configuration menu by pressing Key-ENTER for 5 seconds.
– Press Key-DOWN. You will see ID: 1 = 5
– Press Key-1 until you see ID:1 = 8
– Press Key-4 to leave configuration menu.
After power off/on, the NMEA baudrate will be set to 38400.
Example 2 :
In this example we configure the bridge, so that it will read NMEA data from it's
RS232-RxD port instead of it's NMEA-IN port.
– Find function ID for NMEA-IN port in table on page 22.
– Function ID for baudrate is 34
– Find value for RS232 port in table on page 22.
– Value for RS232 port is 0
34 0 = Input is RS232 port
1 = Input is NMEA port
- Enter Configuration menu by pressing Key-ENTER for 5 seconds.
– Press Key-DOWN until you will see ID: 34 = 1
– Press Key-2 until you see ID: 34 = 0
– Press Key-4 to leave configuration menu.
After power off/on, the NMEA-IN port will be RS232 port.
SeaTalk NMEA Bridge 128SD Sw Version 3.01 Page 20 of 28