Raymarine RS232 Installation Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
20
PC/SeaTalk/NMEA Interface Box
Chapter 4: Fault Finding
All Raymarine products are comprehensively tested prior to packing
and shipment. In the unlikely event that a fault does occur, the
following check list should help cure the problem.
Fault Cause Action
No operation No power supply Check the SeaTalk bus
connectors are correct
between the Interface box
and the power supply.
NMEA data not converted Equipment not set up to Refer to the manufacturers
and transmitted onto the transmit correct NMEA operating handbook.
SeaTalk bus. sentences.
Interface box incorrectly Check connections.
wired.
Variable information, such
as XTE, bearing to
waypoint, Lat/Lon already
on SeaTalk bus.
Required NMEA Information not present Connect required SeaTalk
information not on SeaTalk bus. Instruments.
transmitted from the
interface box.
Main alarm does not 30 second alarm delay Refer to Section 3.4.
sound. applicable.
166_3chs.p65 24/01/02, 11:2120