30 ST60+ Depth Instrument Owner’s Handbook
Shallow alarm lock
When set to On, the shallow alarm lock prevents inadvertent alteration to the
shallow depth alarm setting.
Note:
The procedure for setting alarm level levels is given in Chapter 1, Operation.
Pop-up pilot
Switches the pop-up pilot function on and off.
Leaving User calibration
Hold down the depth and alarm buttons for 2 seconds to save your settings, exit
User calibration and resume normal operation.
4.3 Intermediate calibration
Intermediate calibration enables you to:
Check the instrument software version.
Set the instrument status - either MASTER or REPEATER .
To access the Intermediate calibration screens, hold down the depth and alarm
buttons for approximately 4 seconds. the software version screen is displayed.
To set the instrument status:
1. Press the
depth button to select the Instrument status screen.
2. Press the
offset and reset buttons simultaneously to enter adjust mode,
then press either
offset or reset to set the required status.
Note:
You must not allocate more than one MASTER depth instrument in any system.
Intermediate calibration
Software
version
Instrument
status
Hold down for approximately 4 seconds
depth alarm
+
(or REPEATER)
depth
depth
D8166-1