34 ST60+ Tridata Instrument Owner’s Handbook
Set speed resolution
Select resolution of either 0.01 or 0.1 as required.
Set log units
Select either NM (nautical miles), SM (statute miles) or KM (kilometres), as
required.
Setting the correct speed
Set the displayed (current) speed using one of the following methods:
If SOG is available from SeaTalk, use the Adjust to SOG screen to automati-
cally set the current speed to. You must be running in slack tide conditions to
successfully use this method.
Manually apply a calibration factor by means of the Cal factor adjust screen,
to set the displayed speed value to your best estimate of the vessel’s speed.
If neither of the above methods is suitable, use the
Speed calibration
procedure
described under
Intermediate calibration
to carry out a speed calibration run over
a measured distance. This enables the instrument to calculate the correct
calibration factor.
Adjust to SOG
The Adjust to SOG screen is displayed only if SOG data is available from SeaTalk.
The current SOG is displayed in the bottom section of the display (SG12.8 in the
illustration), and the current speed registered by the instrument, as large figures
in the middle section of the display (12.3 in the illustration).
It is recommended that, if you are running in slack tide conditions, you press the
reset button for 3 seconds, to accept the SOG as the current speed.
If you do not wish to accept SOG as the current speed, press the
trip and reset
buttons together to select the Cal factor adjust display.
Cal factor adjust
The Cal factor adjust screen enables you to manually adjust the calibration factor.
It shows the current calibration factor in the bottom section of the display (CF
1.00 in the illustration), and the current speed as large figures (12.3 in the
illustration).
Use the
trip or reset button to adjust the calibration factor so that the current
speed is the speed through the water.
If SOG data is available from SeaTalk, you can turn to the Adjust to SOG screen by
pressing the
trip and reset button s.
Note:
If neither of the above methods gives satisfactory results, carry out the Speed cali-
bration procedure (part of Intermediate calibration).