Page view 16
Chapter 1: Operation
5
Setting alarm conditions
The alarm threshold screens are accessed with the disp key (see the
Using the
disp
key flow chart), and enable you to switch alarms on or
off and set the alarm thresholds. The alarm threshold screens are:
Maximum true wind speed alarm.
Low true wind speed alarm.
High apparent wind angle alarm.
Low apparent wind angle alarm.
To set up an alarm, carry out the Switching alarms on and off, and
Setting alarm threshold procedures, as necessary.
Switching alarms on and off
Use the disp key to display the required threshold screen, then press
the tack key for approximately one-second, to toggle the alarm either
on (i.e. so the alarm threshold value is displayed) or OFF, as required.
Setting alarm thresholds
To set the required alarm threshold:
1. Use the disp key to display the required threshold screen, then
momentarily press the vmg and tack keys to enter the threshold
adjust mode (indicated by the displayed value flashing).
2. Use the vmg (decrement) or tack (increment) key to set the
required threshold value. You can set:
The maximum (MAX) and minimum (LO) true wind speed, to
any value between 0 and 99 kts. Conflicting threshold values
cannot be set, i.e. you cannot set the MAX threshold to a lower
value than the LO.
High (HI) and low (LO) apparent wind angle, to any value from
0 to 180
o
.
3. Momentarily press the vmg and tack keys to leave the threshold
adjust mode.
Note: The alarm threshold screens are not available on repeater
instruments so alarm thresholds can be set up only on master
instruments.