Chapter 4: Calibration 25
Chapter 4: Calibration
4.1 Introduction
The ST60 Wind instruments are set up with factory-programmed
default settings, so in order to optimise the performance of the
instruments on board a particular vessel, the procedures in this Chapter
must be carried out immediately after the completion of installation,
and before the equipment is used for navigational purposes.
Where practicable, the calibration procedures are presented
diagrammatically to show the sequence of key presses and the
resulting displays. Adjustment instructions are given as applicable.
EMC conformance
Always check the installation before going to sea to make sure that
it is not affected by radio transmissions, engine starting etc.
In some installations, it may not be possible to prevent the
equipment from being affected by external influences. Although
this will not damage the equipment, it can lead to spurious resetting
action, or momentarily may result in faulty operation.
4.2 User calibration
The User calibration procedures:
Linearise and align the wind transducer.
Select the required wind speed units
Linearising and aligning the wind transducer
This procedure ensures that the sensors in the windvane transducer are
correctly calibrated to record rotation of the windvane, then
compensates for any small errors which may exist in the alignment of
the wind transducer.
To do this:
1. Power-up the ST60 Wind instrument.
2. Slowly turn the vessel through two complete circles. This
procedure automatically linearises the windvane. A successful
linearisation is indicated by the digital display flashing and the
buzzer sounding three beeps.