Chapter 3: Installation
23
To fit a power cable:
1. Run the cable from the instrument to a suitable 12 V dc power
source.
Power connections for stand-alone instrument
12 V dc
supply
3 A over-current
circuit breaker
Red
Screen
D4310-4
2. If the cable has not already been trimmed at the power supply end:
a. Cut the cable to length and trim back an appropriate amount
of the outer sheath.
b. Cut back and insulate the yellow wire.
3. Connect the screen to the power supply 0 v terminal.
4. Connect the red wire via a 3 A over-current circuit breaker to the
power supply +12 V terminal.
105_3c03.p65 06/04/01, 10:4723