7-14 hsb
2
PLUS Series Color LCD Display
Bearing Alignment
To change the range scale, highlight the required range and use the soft
keys to change the value. Start at the top of the list and work down, since
each value must be greater than the value for the previous range in the list.
The following scale increments are available:
When you have finished setting up the new scale, press ENTER to return to
the Radar Set Up Menu, and press the ON soft key to select your new
scale.
Bearing Alignment
The bearing alignment is normally set when you first install your system,
and is described in Radar System Checks and Adjustments on page 8-17.
The bearing alignment corrects for display azimuth error. It can be set to a
value in the range -180° to +179.5°, in increments of 0.5°.
Antenna Size
Thisoptionisusedtospecifythesizeof an open arrayscanner.Refer tothe
Pathfinder ScannerOwners handbookfor furtherdetails.
Send on HSB
SEND ON HSB canbe usedto stopradardata beingtransmitted onhsb
2
.
If SEND ON HSB is set to OFF, you can viewyourradar data on themaster
display,but not on a repeaterdisplay.
Table 7-4: Radar Range Scale Increments
Range Scales (nm) Scale Increments (nm)
0.125 to 0.5 0.125
0.5 to 3.0 0.25
3.0 to 6.0 0.5
6.0 to 24.0 2.0
24 to maximum for scanner 4.0